100Expected battery life at this temperature, compared with its life at 25 °C
0power drawn by the system (W)
0required battery energy (Wh)
0battery (Ah, 12 V)
Power values are approximate, based on typical devices; we confirm them during the site survey using the label ratings of your own devices. For minute-by-minute UPS runtime, use the UPS runtime calculator page.
Basis and sources
- Ceylanpınar: 49.0 °C on July 25, 2025 and 47.8 °C on June 20, 2024 (MGM data, news sources)
- Recorder operating temperatures vary by model; one example model is rated 0 to +40 °C, indoor use only (Ajax NVR specifications)
- In lead-acid batteries, every 10 °C above 25 °C cuts battery life roughly in half (Schneider Electric)
- Calculation assumptions: IP camera 6 W (with infrared at night), recorder 12 W for up to 4 cameras, then +8 W for every additional 8 cameras, alarm/modem 8 W per device; inverter efficiency 85%, lead-acid battery 50% usable capacity.

Let's get your system ready for summer
We handle cabinet ventilation, battery testing and UPS checks in a single visit.